Low or no flow from a Gaggia Classic Pro brew group? Learn how to clean/descale the 3-way solenoid valve to fix the problem. Go start to finish in detail through the easy steps to restore flow to your machine. Learn the symptoms indicating a blockage and the relatively simple process to restore machine performance. Learn what causes the blockage and what you need to know to prevent in the future.

Video Contents/Chapters

00:00 Symptoms & Tools

01:25 Open Machine

04:30 Boiler/Parts Removal

05:00 Solenoid Valve

07:30 Valve Disassembly & Cleaning

09:15 Valve Reassembly

11:55 Valve Installation

13:18 Component Install

17:10 Steam Wand Install

19:15 How to Avoid Problems

Related videos:

Process for older Gaggia Classic machines (most 2019 and earlier Classics sold in North America) see this video:

How To Clean and Rebuild a Gaggia Aluminum Boiler: https://youtu.be/N9i-EH7qXOc

Other resources:

Support Wiki for Gaggia Classic Pro with troubleshooting, usage tips, how to's, manual, diagrams and more:

https://wiki.wholelattelove.com/Gaggia_Classic_Pro

Support Wiki for Gaggia Classic: https://wiki.wholelattelove.com/Gaggia_Classic

Get desclalers, parts, etc.: https://www.wholelattelove.com/

WHOLE LATTE LOVE

Get expert advice on products to best fit your needs. Call the coffee experts at Whole Latte Love:

585-924-7170

Talk to our experts via chat or email: https://www.wholelattelove.com/contact-us

Whole Latte Love on Social Media


► Follow Whole Latte Love on Instagram: https://www.instagram.com/wholelattelove/

► Follow Whole Latte Love on Twitter: https://twitter.com/wholelattelove

► Like Whole Latte Love on Facebook: https://www.facebook.com/WholeLatteLoveOnline/